Bodhost.com has its Data Center based in Chicago Facility of Hurricane
Electric. Our Network Operations Center has an international internet
backbone is considered to be one of the best connections world-wide. Some of
the names include Level(3), Abovenet, Savvis, PCCW, Telia and Cogent.
Connections ranging from OC192, OC48, and 10GigE (10,000Mbps) form rings
connecting Hurricane core routers.
An in-house developed self-healing network architecture ensures that there
are no blackholes or failure points within the core network. On top of our
own backbone, as part of our redundancy program we also have multiple Tier
III connections from different locations. This also assures that your data
arrives via the shortest and the fastest available network route.
Our negotiations with the top fiber carriers for new routes and additional
backup transit providers is yet under development. We are also plan to
signup with new peering relationships in the near future.
Hurricane Electric's network utilizes Border Gateway Protocol Version 4
(BGP4) over dark fiber and long haul wavelengths. We always update the
router's software after we have stress tested the latest software on a
non-critical router, to make sure it is very stable. The switch that your
equipment will ultimately be connected to is connected back to a core router
via fiber. All equipments & parts used are branded. So you never have to
worry about hardware failure.
| BODHost Data Center Infrastructure |
| Structure: |
Steel
frame with concrete
slabs and concrete
fireproof. |
| Facade: |
Aluminum window
system and gold tinted
windows. |
| Roof: |
Roof space is limited
to mechanical structures.
Racks and additional
equipment can be located
on the 16th floor
Tower Data Center. |
| Floor
Loading: |
50 - 80 pounds per
sq. ft. live load
(can be reinforced
at column lines). |
| Ceiling
Heights: |
Slab to slab: 13
ft, to lowest beams:
9'-11" |
| Column
Distance: |
28 ft. x 28 to 32
ft. |
| Electrical
Capacity: |
Typical power allocation
is approximately 40
watts per sq. ft.
expandable to 80 watts
per sq. ft. Each cabinet
and 4' x 6' cage receives
a 110 volt, 20 amp
circuit. Main power
is 480 volt, 3 phase.Multiple
DC power supplies
are now available. |
| Elevators: |
Five passenger service
elevator operate during
regular business hours.
Two secure passenger
elevators operate
during non-business
hours. One freight
elevator with a 3,500-pound
capacity. |
| Fire
Suppression: |
Existing wet system
can be converted to
a pre-action system.
FM-200 system can
be installed. Meet-Me
Room is a zoned pre-action
system. |
| Security: |
Manned, on-site
security is present
24/7/365. Keycard
system is in place
for after-hours building
entry and floor access. |
| Risers: |
Fully master-planned
riser system, providing
diverse riser capacity
for fiber, HVAC piping,
electric and fuel
riser needs.
|
| Parking: |
Underground gated
parking area, not
open to public access. |
| Delivery
Area Loading: |
A loading area in
the surface lot at
the south side of
the building is available
to tenants for delivery
of equipment. |
| Operating
Engineers: |
On-site operating
engineers to support
building systems and
provide tenant service. |
| Other
Core Systems: |
On-site building
engineers available
for tenant service. |
| Primary
Power: |
Market Post Tower
has 480 volt, 3-phase
power delivered to
the central power
riser on each floor
via a conduit riser
system. Power allocated
is based on the tenant's
actual demonstrated
loads. Typical power
allocation is approximately
40 watts per sq. ft.
expandable to 80 watts
per sq. ft. |
| Emergency
Power: |
The Landlord has
a 900 KW generator
and a 500 KW generator.
Generator power is
brought to the power
riser on each floor
through a conduit
riser system.Two 2000
KW generators will
be added as demand
increases. |
| Fuel
Storage: |
Market Post Tower
has existing fuel
storage and containment
and associated pumping
for 24 hours of continuous
generator use. |
| HVAC
Dedicated Cooling: |
We have installed
a new, fully redundant,
1,500-ton condenser
water system with
tenant tap-ins pre-installed
in one of the wet
risers on each floor.
|
|